The minimum clear height over stairs serving a single dwelling unit is 1 950 mm (6'-4 3/4"), which is lower than the 2 050 mm (6'-8 3/4") required for most other stairs. The governing provision in the national model code is Article 9.8.2.2.
How headroom is measured
Clear height is measured vertically, over the clear width of the stair, from a straight line tangent to the tread and landing nosings to the lowest point above [Source: National Building Code of Canada 2025, Page 882, Section 9.8.2.2.(1)]. The lowest point could be a ceiling, beam, duct, light fixture or sprinkler head.
National requirement
- The general minimum is 2 050 mm (80 3/4") [Source: National Building Code of Canada 2025, Page 882, Section 9.8.2.2.(2)].
- Stairs serving a single dwelling unit, or a house with a secondary suite (including their common spaces), shall not have less than 1 950 mm (76 3/4") [Source: National Building Code of Canada 2025, Page 882, Section 9.8.2.2.(3)].
- Stairs located under beams and ducting in secondary suites shall not be less than 1 850 mm (72 7/8") [Source: National Building Code of Canada 2025, Page 882, Section 9.8.2.2.(4)].
- These provisions are subject to Article 9.8.4.7., which governs spiral stairs [Source: National Building Code of Canada 2025, Page 882, Section 9.8.2.2.(3)].
The 2020 edition of the NBC contains the same values [Source: National Building Code of Canada 2020, Page 844, Section 9.8.2.2.(3)]. The Illustrated User's Guide explains that the lower dwelling unit minimum is rationalized on the basis of greater occupant familiarity (note: this is commentary, not the regulation itself) [Source: NBCC 2020 Illustrated Users Guide - Part 9 Div B, Page 89, Section 9.8.2.2].